Ex II 1G Ex ia IIB T4 Ga / Ex II 2G Ex ib IIB T3 Gb (according to variant)
Type Approval Atex
FTZU 20 ATEX 0067X (2014/34/EU)
Evc Type According to Mid
volume corrector Type 1
Variants
PTZ / T-corrector
Maximum Error According to Mid
0.5 (%)
Typical Error
0.15 (%)
Dimensions
234 x 182 x 61 (W x H x D, mm)
Ingress Protection
IP 66, outdoor conditions (EN 60529)
Environment Temperature
-25 to +70 Degree C (optionally from -40 Degree )
Temperature Transducer Type
EDT 124
Standard Measuring Ranges
-25 to +70 Degree C
Battery Type
Lithium battery, D cell, SAFT LS 33600 (3,6V/17Ah)
Battery Life
5 years
Product Description:
ECLOR is the electronic volume corrector used with various types of RPD and Turbine meters. The device's design with respect for future extensibility enables the customer an easy extension of the functions, which in the case of ELCOR model means the possibility of modem installation or replacing an existing modem with a newer one in the future.
The basic features of the ELCORlite are the integrated RS232 / RS485 serial interface, allowing connection to the data collecting / SCADA system, 3 digital inputs (low frequency or binary), 2 digital outputs and the option to connect the NAMUR or SCR + encoder interface. A maximum of 1 pressure transducer and 1 temperature transducer can be connected.
The extended measuring ranges of the pressure transducers make it easier for the customer to order a corrector.
The ELCORlite is also available in a version capable of measuring and operating in temperatures from -40 °C.
All communication interfaces are mutually independent.
The ELCORlite includes a data logger as an integral part of the device with a large 16MB memory, allowing to store measured data at hourly intervals for more than 10 years.
The housing was designed to operate in harsh outdoor environments with certified IP66 protection class.
Basic Features
Single-channel gas volume corrector
Modular design
High accuracy and stability of measurement
The battery life of up to 11 years for a corrector and 11 years for a modem (HB-03D battery) under defined conditions
1x digital pressure transducer EDT96, 1x digital temperature transducer EDT101 with extended measuring ranges
Pressure measuring range up to 130 bar
High memory capacity for storing of measured values
Version for operating in temperatures from -40 °C
Two variants of LCD display - graphical display (allowing full interaction with the device) or segment display (constantly illuminated - non-switched off)
Robust design with IP 66 protection suitable for outdoor installation
Fully configurable device via supplied software
Designed for a potentially explosive environment in Zones 0, 1 and 2
Metrological approval according to MID: TCM 143 / 18-5562
ATEX certificate FTZÚ 17 ATEX 0143X
Communication
3 independent communication interfaces with supported speed up to 115,200 Bd
Optional integrated modem
Modems for 2G, 3G, 4G, NB (Narrow Band) networks available
Support for an external modem connected via serial interface
IEC 62056-21 optical interface (IEC-1107) with supported sp